韩应超,杨明杰,潘 杰,王善金,郭 松,麻 彬,王 强,张东升,李立钧,谭 军.单纯寰椎侧块螺钉固定选择性治疗不稳定寰椎骨折的生物力学分析[J].中国脊柱脊髓杂志,2014,(1):68-73.
单纯寰椎侧块螺钉固定选择性治疗不稳定寰椎骨折的生物力学分析
中文关键词:  寰枢椎  侧块螺钉  生物力学  韧带
中文摘要:
  【摘要】 目的:测试单纯寰椎侧块螺钉固定治疗不稳定寰椎骨折的生物力学稳定性,为临床应用提供理论依据。方法:取新鲜成人的完整枕骨及颈椎(C0-C3)标本6具,聚甲基丙烯酸甲酯包埋,在电子生物力学试验机上分别测定完整标本(A组),寰椎骨折合并横韧带离断+寰椎侧块螺钉固定(B组),横韧带、纵向韧带离断+寰椎侧块螺钉固定(C组)的前屈/后伸、左/右侧屈的运动变化以及前屈时C1-2的相对位移ADI(atlantodental interval)值,进行统计学分析,评价单纯寰椎侧块螺钉固定治疗不稳定寰椎骨折的生物力学稳定性,分析上颈椎韧带复合体的生物力学作用。结果:寰椎横韧带切断内固定后,载荷为50~90N时,A组与B组的ADI值、前屈、后伸相比,无统计学差异(P>0.05);当载荷为100N时,B组ADI值2.76mm、前屈11.66°、后伸14.05°,载荷为150N时,B组ADI值3.15mm、前屈15.27°、后伸16.25°,与A组相比均有统计学差异(P<0.05)。横韧带切断后,载荷小于100N时,B组左、右侧屈与A组比较差异均无统计学意义(P>0.05);载荷100N时,B组左侧屈7.51°,与A组比较差异无统计学意义(P>0.05),B组右侧屈8.43°,与A组相比存在统计学差异(P<0.05);载荷150N时,B组左侧屈8.79°、右侧屈10.67°,与A组比较均有统计学差异(P<0.05)。进一步切断纵向韧带,稳定性明显丧失,C组的ADI值和前屈、后伸、左右侧屈范围与A组相比均有显著统计学差异(P<0.05)。结论:单纯寰椎侧块螺钉固定治疗寰椎骨折,恢复C0-2之间的高度,即恢复纵向韧带的张力能够维持生理载荷下寰枢椎的稳定性。
Biomechanical analysis of direct posterior C1 screws compression reduction in the selective treatment of unstable atlas fractures
英文关键词:Atlantoaxial joint  Lateral mass screws  Biomechanics  Ligament
英文摘要:
  【Abstract】 Objectives: A biomechanical analysis was performed to investigate the stability of the direct posterior C1 lateral mass screws compression reduction for treatment of instable Jefferson fracture and provide the theoretical basis for clinical applications. Methods: Six fresh cadaveric whole upper cervical spine(UCS) specimens were harvested and embedded in polymethylmethacrylate(PMMA). Three dimensional movements including flexion, extension, right and left lateral bending as well as the C1-2 displacement in flexion(atlantodental interval, ADI) were measured on an electromechanical testing machine by stereophotogrammetry. Specimens were tested in the following states in sequence: the intact specimens were tested(group A), after destabilization of C1-C2, the specimens underwent C1 lateral mass screw fixation(group B), then specimens with transverse ligament and longitudinal ligaments transected(group C) were tested. Results: The motion of ADI, flexion and extension had no signicant difference(P>0.05) between group A and group B under the physiological loading(50-90N). At the loading of 100N and 150N, significant difference was detected between the two groups(P<0.05), at the loading of 100N and 150N, the average of ADI, flexion and extension was 2.76mm, 11.66°, 14.05° and 3.15mm, 15.27°, 16.25°. The motion of left and right lateral bending between group B and group A had no statistical difference indicated under physiological loading range. At the loading of 100N, the average of left lateral bending was 7.51°(P>0.05), whereas significant difference was detected when the loading was more than 150N(P<0.05). The motion of right lateral bending had significant difference when the loading was more than 100N, and at the loading of 100N, 150N, the average of left lateral bending was 8.43°, 10.67°(P<0.05). The three-dimensional motion of group C indicated obvious instability, significant difference was found in the comparison with group A and group B. Conclusions: The stability of atlantoaxial joint can be maintained by collaboration of series of ligaments. The longitudinal ligaments can maintain the stable of atlantoaxial joint under physiological loading range.
投稿时间:2013-02-28  修订日期:2013-12-08
DOI:
基金项目:国家自然科学基金(编号:81171700),2011年上海市卫生局课题资助;上海市浦东新区学科带头人计划资助(PWRd-2011-02)
作者单位
韩应超 同济大学附属东方医院脊柱外科 200120 上海市 
杨明杰 同济大学附属东方医院脊柱外科 200120 上海市 
潘 杰 同济大学附属东方医院脊柱外科 200120 上海市 
王善金  
郭 松  
麻 彬  
王 强  
张东升  
李立钧  
谭 军  
摘要点击次数: 3256
全文下载次数: 2211
查看全文  查看/发表评论  下载PDF阅读器
关闭